Vallitech

VLT-900 Electric ICU Fowler Bed (Reduced Width)

It is a medical-surgical bed designed to be easy to use, without sacrificing advanced features that make day-to-day care of acute patients easier. With features that simplify the routine for nurses and caregivers, it guarantees maximum patient safety, while facilitating and encouraging mobility.

Design. Comfort. Resistance. Durability.

Vallitech beds are designed and manufactured to ensure that day-to-day use in the hospital does not cause premature and/or permanent wear to the equipment.
They are produced with a high quality carbon steel structure, coated with electrostatic paint and designed with the help of finite element engineering software, which simulates the stresses and strains of severe use within a hospital.
With these results, it is possible to predict and reinforce the main points of demand, giving the product a much longer service life.
They are tested exhaustively in the laboratory and at the factory to guarantee an extended service life of 10 years, without noise, vibrations or deformations.

The VLT-900 bed was developed to fit the dimensions of hospitals in general. It has a short length and width, which makes it easier to transport and reduces the space needed for its use. These characteristics, combined with its low height, make it easier for patients to use and for nurses to handle. Grids with high dimensions provide greater safety, reducing the risk of falls and allowing the use of mattresses with greater heights, within the normative safety standards. The grid movement mechanism requires less space to operate, while still reducing the lateral spaces required. It has an abdominal compensation system in the back (double pivoting axis), which reduces abdominal pressure when moving the dorsal section.

LAYOUT

The bed has 4 sections and can be made from painted sheet steel or blown high-density polyethylene (removable for easy cleaning). It has vents for ventilating the mattress, specific points for restraining the patient along its entire length and hooks for collection bags.

HEADBOARD AND FOOTBOARD

Removable, blown in high-density polyethylene.

SIDE GUARD RAILS

Articulated, blown in high-density polyethylene, with unlocking and articulation mechanisms towards the side of the bed, moving only 6.5 cm to lower the rail, using a reduced lateral space. Its height of 40 cm from the bed provides greater safety for the user. It has built-in indicators for the angle of inclination of the back and trendelemburg.

MOVEMENTS

Powered by electric motors, controlled by membrane keypads on the side rails (internal and external). The control on the back is optional. Through the internal membranes, only the movements of the back, legs and night light are accessible to the patient. On the external nursing side, it is possible to control all the bed's movements, as well as programmed positions such as armchair, self-contouring, trendelemburg, reverse trendelemburg, as well as individual blocking of motor functions.

WHEELS

Central brake pedal system with directional wheel located near the foot of the bed, with optional individual brakes on the castors.




Inmetro
Total length 2.19 m (± 0.01 m)
Total length with extender (optional) 2.54 m (± 0.01 m)
Width with rails up 0.88 m (± 0.01 m)
Height variation 0.37 m - 0.71 m (± 0.01 m)
Mattress platform 0.73 m × 1.99 m (± 0.01 m)
Degree of maximum back 65º
Maximum degree of leg 30º
Trendelenburg 12º
Reverse Trendelenburg -12º
Height of the rails from the mattress platform 40 cm
Maximum mattress height indicated 16 cm
Maximum safety load 250 kg
Abdominal compensation when lifting the back section
(double pivoting axis)
11 cm
Grille lateral clearance when retracting (lowering) 6,5 cm
Castor dimensions 100, 125 and 150 mm
Brake system Pedal center (standard) or individual on casters (optional)
Round 5 Optional
Mechanical and electronic CPR Optional
Radiotransparent back (x-ray) Optional
Bed extender (31 cm) Optional
Oxygen holder Optional
Removable headboard and footboard Standard
Heart position button Standard
Side rails Polyethylene
Socket for IV support on the 4 corners of the bed Standard
Night light Standard
Back degree indicator Standard
Trendelemburg and reverse Trendelemburg grade indicator Standard
Membrane keypads on the grilles Internal and external (standard)
Headrest (optional)
Wired control (optional)
Collection bag holder Standard
Bed Painted sheet metal (standard)
ABS (optional)
Location for patient restriction Standard
Self-contouring Standard
IV stand Optional
Keyboard on the bed Optional
Patient exit alarms Optional
Seated Patient Alarm Optional
Skin pressure alarm Optional
Fall risk alarm Optional
Brake activated alarm Optional
Back alarm 30º Optional
Nurse call Optional
Minimum height indicator Optional
Remote monitoring Optional
Food 100 - 240 VAC, 50 - 60 Hz
Battery backup Yes
Protection against water IPX4
Regulatory standards IEC 60601-1
IEC 6.0601-2-52
IEC 60601-1-2

 

CONNECTIVITY (OPTIONAL)

 

Vallitech.Connectivity

Compatible with the Vallitech monitoring system, which makes it possible to view and monitor the bed's condition online from the nursing station.

With this system it is possible to activate alarms that reduce the risk of falls, skin pressure, patient escape, prevent patients from sitting up in bed, monitor brakes, rail positions, minimum bed height and degree of back (lung).

Nurse call is also a function of this system. Once any alarm has been activated via the bed keypads, if an unwanted activity (e.g. lowering a railing) is carried out, an alarm is triggered on the nursing station's monitoring screen, and the time taken for the alarm to be answered is also controlled by the nursing staff.

The entire history of calls and alarms is recorded for later reference.


ABDOMINAL COMPENSATION SYSTEM

 

Abdominal compensation system designed to reduce pressure on the patient's abdomen, where a 110 mm offset in the back is made during movement. Standard system for G-021 rails.


SIDE GUARD RAILS CERTIFIED TO ABNT NBR IEC 60601-2-52:2013

 

Headboard/Footboard and Grids Set (C-032 headboard and G-023 grids). Hinged side protection rails in high-density polyethylene, certified to the new ABNT NBR IEC 60601-2-52:2013 standard, which standardizes patient safety measures such as:

  • minimum rail height of 220 mm (above the mattress) covering more than 50% of the bed,
  • spacing of less than 60 mm between the side rails and between the headboard and the side rails,
  • recessed openings in the rails/headboard/chest smaller than 120 mm and other spacing to avoid trapping the neck, chest and head.

It has a mechanism for unlocking and moving the bed sideways, allowing it to be retracted under the bed, facilitating patient transfer and avoiding problems with probed patients.


VLT-900 Detail Grids


LAYOUT

HEAD

VLT-900 Headboard
OPTION: Reduced width (0.86 m) Headboard C-031. Optional: gray sticker.

CLEANING

POSTURE

Cleaning the bed VLT-900 Posture
Easy and immediate access for maintenance, cleaning and disinfection tasks (optional thermoplastic bed).

 

Shopping Cart